  Datasheet File OCR Text:
 Pre-amplified/5V Excitation/Gauge
Features
. . . . . Two accuracy ranks, 1.5 FS and 2.5 FS available Volt level output On-chip amplification and temperature compensations Pre-calibration of offset voltage and span Non-corrosive liquid measurable (XFGMC only)
XFGM-3,XFGM-6 Data sheet
Applications
. Industrial instrumentation . Pressure switch, Pneumatic device . Medical device
Part number for ordering
XFGM C - 3 025KP G S R H
Model XFGM Rated pressure (Pa) Length of the pressure port 3 : 3mm 6 : 6mm
Accuracy
No mark : H :
2.5 1.5
FS FS
(Contact us about availability)
Terminal leads direction(See Outline Diagram) R:
Available pressure media No mark : Non-corrosive gas only C : Non-corrosive gas and liquid
(Contact us about availability)
Terminal leads configuration S : Surface mount package Pressure type G : Gauge (Positive pressure) GV : Gauge (Negative pressure) GW : Gauge (Bipolar pressure)
Gauge pressure
Pressure type XFGM-3
XFGM-6
Model
Package configuration Measurable pressure range (kPa) 100 100 0 100 0 25 0 50 0 100 0 200 0 1000
Surface mount package, 3mm pressure port
Surface mount package, 6mm pressure port
Part number for ordering XFGM-3100KPGWSR XFGM-3100KPGVSR XFGM-3025KPGSR XFGM-3050KPGSR XFGM-3100KPGSR XFGM-3200KPGSR XFGM-3001MPGSR XFGM-6100KPGWSR XFGM-6100KPGVSR XFGM-6025KPGSR XFGM-6050KPGSR XFGM-6100KPGSR XFGM-6200KPGSR XFGM-6001MPGSR
Specifications
Model/Rated pressure 100KPGW 100KPGV 025KPG 050KPG 100KPG 200KPG 001MPG Unit Recommended operating conditions Pressure type Gauge pressure 100 100 25 50 100 200 Rated pressure 1.020 1.020 0.255 0.510 1.020 2.040 Measurable pressure range 100 100 0 100 0 25 0 50 0 100 0 200 Pressure media 1 XFGM : Non-corrosive gas only, XFGMC : Non-corrosive gas and liquid Excitation voltage 5.0 0.25 Absolute maximum rating Maximum load pressure Twice of rated pressure Maximum excitation voltage 8 Operating temperature 40 125 Storage temperature 40 125 Operating humidity 30 80(No dew condensation) Electric performances/characteristics (Excitation voltage Vcc=5.0V constant, Ambient temperature Ta=25 ) Current consumption less than 10 Output impedance less than 10 Source current less than 0.2 Sink current less than 2 Mechanical response time 2 (For the reference) Full scale span voltage 4.5 Offset voltage 1.2 0.2 0.1125, 0.2 0.0675(H) Full scale span voltage 1.2 4.7 0.1125, 4.7 0.0675(H) Accuracy 1.2 2.5, 1.5(H)
Note ; 1) Please consult us available when you choose the C models and the H models. 2) Excluding input voltage error.
1000 10.20 0 1000
kPa kg/cm2 kPa VDC
1.5times of rated pressure VDC
RH mA mA mA msec V V V FS/0 85
1
Pre-amplified/5V Excitation/Gauge
Outline dimensions
XFGM-3,XFGM-6 Data sheet
unit : mm
XFGM-3
2.54 2.54 Pressure port 1 2 3 0.8
7 6
5 7
4 3
Vent hole
Index 3 0.15 6.5
0.8 10.3
15
MA
X.
0.25
3.5
Recommended footprint for PCB
6 5 4 Labelled faceplate
1.4 1.7 2.54 2.54 9.4
1
1
2
3
Land-pads
(unit : mm)
unit : mm
XFGM-6
Pressure port 1
2.54 2.54 0.8 2 3
7 6
5 7
4 3
Vent hole
Index 6 9.5
0.8 10.3
15
MA
Projections
0.5
X.
0.25
3.5
6
5
4
2-R0.5
Recommended footprint for PCB
1.7 1.4 2- 1(Holes for projections) 2.54 2.54 6.0 9.4
1
Projections
1
2
3
Labelled faceplate
Land-pads
(unit : mm)
2
6.0
Pre-amplified/5V Excitation/Gauge
Connection diagram
XFGM-3,XFGM-6 Data sheet
XFGM-3, FGM-6
Vcc
Vcc(DC5V)
Vout Vout GND C2 C1
Remarks : 1) C1 : Connect 680pF capacitor within 2cm distance from leads. 2) C2 : Connect 0.01 F or more capacitor within 2cm distance from leads. GND 3) 4 and 5 pins must be No Connection. Open them as floating ones completely, and do NOT connect to other line or each other.
Transfer Function
Vout=Vs (P Vs=5.0volts
Notes ; The output voltage (Vout) is no perfect ratiometric with the power supply voltage.
+ ) (Pressure Error Temperature Error Multiplier
Vs)
P=Input Pressure(kPa)
Model 025KPG(D) 050KPG(D) 100KPG(D) 100KPGV 100KPGW(DW) 200KPG(D) 001MPG(D) 115KPA pressure range 0 25kPa 0 50kPa 0 100kPa 0 100kPa 100 +100kPa 0 200kPa 0 1MPa 15 115kPa.abs 0.036 0.018 0.009 0.009 0.0045 0.0045 0.0009 0.009 0.04 0.04 0.04 0.04 0.49 0.04 0.04 0.095 Pressure Error(kPa) 0.625 1.25 2.5 2.5 5.0 5.0 25 2.5
Temperature Error Multiplier
3.5
Temperature Error Multiplier
3 2.5 2 1.5 1 0.5 0 -40 85 125 120
-20
0
20
40 Temperature
60
80
100
Note ; Please read instruction "Notes" before using the sensor. Fujikura reserves the right to change specifications without notice.
If you have any questions regarding technical issues or specifications, please contact us. Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-1538 3 E-mail : sensor@fujikura.co.jp


▲Up To Search▲   

 
Price & Availability of XFGMC-3025KPGSRH

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X